April 2010 - Latest LoadRunner Bugs and KB Articles
Web/AJAX Protocol:
KM840444 - Using the Web HTTP/HTML protocol in LoadRunner 9.51 or 9.52, after recording the business process the body portion is missing in the web_custom_request when the script is generated. No error message is displayed in the log files, either during record or replay.
For example, with LR
9.50 the recording of an HTTP POST request to a SAP server generates the
following web_custom_request code: An internal defect was introduced
into the LoadRunner Web HTTP/HTML recording engine at release 9.51 (SP1)
onwards. In some cases the problem may
be avoided by choosing a different recording option. If the VuGen ->
Recording Options -> General is set to URL mode, try removing the URL
Advanced option Use web_custom_request only if
this option has been set. The fix for this problem is built on LoadRunner 9.52
and is available in patch LR95P108 on the support site.
The patch must only be applied to LoadRunner 9.52.
<snip>
web_custom_request("runtime_2",
"URL=http://hostname.domain.org:50000/xxx/yyy/zzzzz",
"Method=POST",
"Resource=0",
"RecContentType=text/html",
"Referer=URL=http://hostname.domain.org:50000/xxx/yyy/zzzzz",
"Snapshot=t28.inf",
"Mode=HTTP",
"Body=<body
content>",
LAST);
<snip>
After
updating to LoadRunner 9.51. (SP1) or 9.52 (SP2), recording the same
business process generates the following code:
<snip>
"web_custom_request("runtime_2",
"URL=http://hostname.domain.org:50000/xxx/yyy/zzzzz",
"Method=POST",
"Resource=0",
"RecContentType=text/html",
"Referer=URL=http://hostname.domain.org:50000/xxx/yyy/zzzzz",
"Snapshot=t16.inf",
"Mode=HTTP",
LAST);
<snip>
KM829038 - 'Error -27717: Invalid NTLM type 2
message: "NTLM"' is displayed when trying to replay a script against an
HTTPS web site using the “Use automatic configuration script” option. This is a LoadRunner limitation.
Vusers cannot access HTTPS resources through NTLM proxy, obtained from
the proxy auto-configuration file (pac). Specifying the proxy server
details in the Run-time settings instead of the pac file.
KM887311 - During the replay of Ajax Click & Script (C&S)
the following
message appears:
"Warning -26276: JavaScript error (id=0) in
line XXX: Event onDOMContentLoaded is not supported for "Document" DOM
object"
This function onDOMContentLoaded is not supported by Internet Explorer (IE) 6.0 so LoadRunner C&S solution cannot be used here. Try to use the HTTP/HTML protocol.
Flex/AMF Protocol:
KM825596 - When recording a script using the Flex protocol, occasionally the RTMP calls may be recorded in the incorrect order in the script.
The following is the order of the events as we
recorded them: HTTP requestt (amf) -> TCP recv (RTMP) <- TCP send (RTMP) -> HTTP response (amf) <- The problem is that in HTTP level (amf call) we refer
to the request+response as 1 item (since we generate one step for both),
while in TCP level (RTMP) recv and send are independent steps. You can refer to it as a different level of
resolution, different levels of API. Since HTTP resolution is lower, we have to create the
one web step in one of the possible locations - before the recv or after
the send. Our policy is to generate according to the timing of
the last event (which is the timing of the response) and not according
to the timing of the first event (request sent). Of course none of these two policies is perfect, and
each one of them may fail in different cases. This is considered a limitation.
KM838715 - The duplicate AMF calls appear in the recording log as well as in the generated code. Capture level is currently set to Socket and WinInet.
KM851819 - Black screenshots appear during recording/replay when using Citrix Presentation server 4.0 and 4.5.
To correct this:
NOTE: This limitation is documented in the LoadRunner
"readme.htm" release notes for LoadRunner 9.5 SP1 and 9.5 SP2.
KM855459 - The solution to this problem is to use the documented workaround:
Workaround: When recording, set the window size equal to the local screen resolution. When replaying/load testing, set the VuGen or Load Generator's screen resolution to equal the resolution used when the script was recorded. To verify the recorded resolution, view the Window property in the <Script Folder>\default.cfg file.
Other:
KM860635 - Controller fails to display the graph measurements when sitescope version 10.0 is added as a monitor engine.Specifying a monitored machine name using a fully qualified domain name or IP address, the Controller will fail to display the default graph measurements.
This is a limitation in LoadRunner
9.52. Instead of providing fully qualified domain name or IP address,
specify only the actual machine name (without any domain suffix)
KM860995 - There are two ways a SAML token can be created with the web services protocol:
If a Security Token Service (STS) is used, i.e. the client asks for the SAML token from the STS (request 1) and then sends it to the server (request 2). If this is the case, create the token using federation scenario. Manage services -> Protocol and security -> new scenario -> WCF - WSFederationHttpBinding
If no Security Token Service (STS) is involved. If the client generates the SAML assertion by itself and also signs it by itself then use ws_sign_saml_assertion() method.
KM865534 - LR9.5 controller crashes on Vista when an action is done on "Add Group" or "Add Vusers" button.
A patch is available for this on the support site. It replaces the scripttree.ocx file.
KM870596 - When it is necessary to upgrade Loadrunner (LR) from version 8.10 and below to version 9.5, user should be aware that there might be not only some loss of information, but also the risk to get unexpected behaviour in Loadrunner.
In these cases it is always recommended to create new
scripts and run them according the new functionality of the newer
versions.
LoadRunner's behaviour in order
to present results has substantially been modified. In order to update LoadRunner's scripts and results files it is
advisable to try an as smooth as possible upgrade of the software. Since only version 9.0 and above is supported, this upgrade has not
been tested, but given the different features newer versions
implement, there is a high risk some data will be lost during the
upgrade process. Using old results files may turn into a bad functionality of LR 9.5.
KM823684 - After installing SP2, a similar
entry to the one below may be seen in the replay log:
Web Turbo Replay of LoadRunner 9.50 SP1 for WINXP;
WebReplay96 build 7049 (Sep 23 2009 17:14:02)
When selecting
Help -> About HP Virtual User Generator the following is seen as
well:
About HP Virtual User Generator
displays 9.52.0.0
for all componenets.
The entry in the replay log (Web Turbo Replay of LoadRunner 9.50 SP1 for WINXP; WebReplay96 build 7049 (Sep 23 2009 17:14:02) ) may be seen because SP2 was developed as a patch to be applied on top of SP1 and because of this there may be cases where LR 9.50 SP1 is shown in the replay log. This can be ignored as SP2 was successfully installed.
KM821875 - When using HP LoadRunner 9.52 (that is LoadRunner 9.5 with both SP1 and SP2 applied) to analyse a results file, the following error message is displayed:
"Errors have occurred while analyzing this
result. Do you want to view the error log?" This may occur when the LoadRunner platform locale (Regional Options -
Standards and formats) is set to a non "English" value e.g. "German
(Germany)". The resulting error log may contain entries as follows: Analysis Error log: <dd.mm.yyyy
hh:mm:ss> Furthermore closing and re-opening the Analysis component results in a
popup being displayed with the text: "Unable to format numbers. Thousands and
decimal separators are equal: "." If the locale is set to "English" opening the Analysis component will
not result with this popup being displayed. Incorrect delimiters may also be observed in the analysis report for
numeric values. Non English locale settings such
as delimiters are incorrectly handled by the LoadRunner Analysis
component. A patch is available to address
this issue in LoadRunner 9.52 on the support web site.
SQL Error: Insert into VuserEvent_meter select * FROM
[Text;
database=C:\DOCUME~1\<username>\LOCALS~1\Temp\].130209606VuserEvent_meter.txt;
ADO :(Could not update; currently locked.):